The LRS-200 is a 200W single-output power supply unit produced by Winston, featuring a slim 30mm design, supporting an input voltage range of 115VAC or 230VAC, selectable via a switch.
This series offers a variety of output voltages, including 4.2V, 5V, 12V, 15V, 24V, 36V, and 48V.
The LRS-200 power supply unit boasts an efficiency of up to 90% and uses natural convection cooling, with an operating temperature range from -25℃ to +70℃, making it suitable for various industrial environments.
MODEL | LRS-200-5 | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 |
DC Output Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Current | 40A | 17A | 14A | 8.8A | 5.9A | 4.4A |
Current Range | 0~40A | 0~17A | 0~14A | 0~8.8A | 0~5.9A | 0~4.4A |
Rated Power | 200W | 204W | 210W | 211.2W | 212.4W | 211.2W |
Ripple &Noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
Voltange ADJ. Range | 4.5~5.5V | 10.2~13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
Voltage Tolerance | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±2.0% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise Time | 1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load | |||||
Hold Up Time | 16ms/230VAC 12ms/115VAC at full load | |||||
Voltage Range | 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC) | |||||
Frequency Range Input | 47 ~ 63Hz | |||||
Efficiency | 87% | 87.5% | 88% | 89.5% | 89.5% | 90% |
AC Current | 4A/115VAC 2.2A/230VAC | |||||
Inrush Current | CCOLD START 60A/115VAC 60A/230VAC | |||||
Input Leakage Current | <2mA/ 240VAC | |||||
Over Load | 110 ~ 140% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
Over Voltage | 5.75~6.75V | 13.8~16.2V | 18~21V | 28.8~33.6V | 41.4~48.6V | 55.2~64.8V |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||
Working Temp. | -20 ~ +70ºC (Refer to "Derating Curve") | |||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||
Storage Temp.,Humidity | 40 ~ +85 , 10 ~ 95% RH | |||||
Temp.Coefficien | ±0.03%/ºC (0~50ºC) | |||||
Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||
Safety Standards | EN60950-1, EN60335-1, EN61558-1 2 16 approved | |||||
Withstand voltage | I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/70% RH | |||||
MTBF | 347.5K hrs min. MIL-HDBK-217F (25ºC) | |||||
Dimension | 215*115*30mm (L*W*H) | |||||
Packing | 0.66kg |
215mm x 115mm x 30mm (L x W x H).
The LRS-200 series of power supply units is an ideal choice in the industrial field due to its high efficiency, high reliability, and wide range of applications.
Ensure the correct input voltage: Choose the appropriate input voltage based on the device requirements and ensure it does not exceed the input voltage range of the power supply.
Load requirements: Do not exceed the power supply's rated load to avoid damaging the power supply or reducing its service life.
Avoid overheating: Although the LRS-200 is designed to operate without a fan, ensure sufficient air circulation for heat dissipation.
Correct connection: Make sure all power connections are secure and correct.
Avoid moisture and dust: Despite the power supply's design for environmental resistance, try to avoid and dusty environments.
Regular inspection: Regularly check the status of the power supply, including checking for overheating, noise, or other abnormalities.
Follow EMC guidelines: If the power supply will be used with sensitive electronic equipment, ensure proper electromagnetic compatibility (EMC) measures are followed.
Pay attention to safety standards: The LRS-200 complies with international safety standards such as UL62368-1; use the power supply in accordance with these standards.
Avoid severe vibration: Although the power supply can withstand vibration tests of up to 5G, try to avoid severe vibration and impact.
Check terminal pin definitions: When installing or maintaining, ensure you understand the terminal pin definitions and make the correct connections.
Storage conditions: Pay attention to temperature and humidity when storing, avoiding extreme conditions.
Follow the product manual: Carefully read and follow the guidelines in the product manual during installation and use.